7-18 Troubleshooting

On-screen error message

Cause

Action

0BD6 3rd SMBus device

 

 

Check cable connection.

address not

 

 

Replace the board.

acknowledged

 

-

 

 

0BD7 3rd SMBus device Error

 

(3rd SMBus does not exist)

 

 

detected

 

 

 

 

0BD8 3rd SMBus timeout

 

 

 

 

0BD9 4th SMBus device

CPU module board #2 is faulty.

 

 

address not

 

 

 

 

acknowledged

 

 

 

 

0BDA 4th SMBus device Error

 

 

 

 

Detected

 

 

 

 

0BDB 4th SMBus device

 

 

 

 

timeout

 

 

 

 

0BDC 5th SMBus device

 

 

 

 

address not

 

 

 

 

acknowledged

 

-

 

 

0BDD 5th SMBus device Error

 

(5th SMBus does not exist)

 

 

detected

 

 

 

 

0BDE 5th SMBus timeout

 

 

 

 

0BDF 6th SMBus device

 

 

 

 

address not

 

 

 

 

acknowledged

 

-

 

 

0BE0 6th SMBus device Error

 

(6th SMBus does not exist)

 

 

detected

 

 

 

 

0BE1 6th SMBus timeout

 

 

 

 

0BE2 7th SMBus device

Back panel board is faulty.

 

 

address not

 

 

 

 

acknowledged

 

 

 

 

0BE3 7th SMBus device Error

 

 

 

 

detected

 

 

 

 

0BE4 7th SMBus timeout

 

 

 

 

0BE5 8th SMBus device

PCI module board #2 is faulty.

 

 

address not

 

 

 

 

acknowledged

 

 

 

 

0BE6 8th SMBus device Error

 

 

 

 

detected

 

 

 

 

0BE7 8th SMBus timeout

 

 

 

 

0BF0 Vendor ID cannot be

Back panel board is faulty.

Replace the back panel board.

retrieved from BP

 

 

 

 

IDPROM

 

 

 

 

0BF1 System Structure cannot

 

 

 

 

be retrieved from BP

 

 

 

 

IDPROM

 

 

 

 

0C00 Rompilot reports error

Configuration error in

Re-configure Rompilot.

number xx

 

SETUP.

Replace the CPU/PCI

 

CPU/PCI module board is

 

module board.

 

 

faulty.

 

 

8600 No working DQS value

DIMM is faulty

Replace DIMM

found

DIMM is not supported

Replace DIMM with

 

 

 

 

appropriate one.