7-34 Troubleshooting

Event Log

Perflib-related logs are recorded in the application event log when system starting:

When system is starting, Perflib log may be registered to the application log.

The detailed information about an event log is described on Microsoft Product Support Services. Please check the contents.

[INFO] Events for Performance Monitor Extensions http://support.microsoft.com/default.aspx?scid=kb;en-us;226494

Application Log Events Generated When You Start Performance Counter Query http://support.microsoft.com/default.aspx?scid=kb;en-us;296187

Event ID 2003 Warning Message Logged When Loading Performance Counters http://support.microsoft.com/default.aspx?scid=kb;en-us;267831

Visit the Microsoft Help and Support on regular basis where you can find other information than the above at: http://support.microsoft.com/default.aspx?LN=en-us.

"The NMS Service terminated unexpectedly." is recorded in the system event log:

Although the following log may be recorded in the system event log when starting the system, or after exchanging PCI modules, there is no real problem on operation. Change of a setup with PROSet II will become invalid if NMS service stops, but you can change a setup normally because NMS service will be automatically started when PROSet II is started.

“Source:

Service Control Manager

Event ID:

7031

Description: The NMS service terminated unexpectedly. This has occurred 1 time(s). The following corrective action will be taken in 0 milliseconds: No action.”

iANSMiniport-related logs are recorded in the system event log:

Although the following log may be recorded in the system event log when starting the system, there is no real problem on operation (In the description, “X” represents a number).

“Source: iANSMiniport

Event ID: 35

Description: Initializing Team #X missing adapters. Check the configuration to verify that all the adapters are present and functioning.”

The logs of the source “iANSMiniport” are the logs about the duplex of the network. The following logs may be recorded in the system event log when starting the system (In the description, “X” represents a number).

“Source: iANSMiniport

Event ID: 11

Description: Adapter link down: Stratus emb-82544GC Copper Gigabit Adapter.”