Indication | STATUS LED | Suspected | Explanation | Procedure | ||
Color | State | module | ||||
|
|
| ||||
CPU2 removed | Green | Blink | CPU module #2 | The CPU module has come | Dismount and remount | |
|
|
|
| off. | the PCI module. If not | |
|
|
|
|
| solved by the above, | |
|
|
|
|
| contact your sales | |
|
|
|
|
| agent. | |
CPU2 Temp Alm | Amber | Blink | CPU module #2 | Temperature alarm (lower | Check to see if dust is | |
00 |
|
|
| limit) | accumulated on the | |
CPU2 Temp Alm | Amber | Lit | CPU module #2 | Fatal temperature alarm (lower | internal fans. Check also | |
02 |
|
|
| limit) | if the fan cables are | |
CPU2 Temp Alm | Amber | Blink | CPU module #2 | Temperature alarm (upper | connected securely. If | |
07 |
|
|
| limit) | not solved by the above, | |
CPU2 Temp Alm | Amber | Lit | CPU module #2 | Fatal temperature alarm | contact your sales | |
09 |
|
|
| (upper limit) | agent. | |
|
|
|
|
|
| |
CPU2 VccpAlm 00 | Amber | Blink | CPU module #2 | CPU operating voltage alarm | Contact your sales | |
|
|
|
| (lower limit) (VCCP) | agent. | |
CPU2 VccpAlm 02 | Amber | Lit | CPU module #2 | Fatal CPU operating voltage |
| |
|
|
|
| alarm (lower limit) (VCCP) |
| |
CPU2 VccpAlm 07 | Amber | Blink | CPU module #2 | CPU operating voltage alarm |
| |
|
|
|
| (upper limit) (VCCP) |
| |
CPU2 VccpAlm 09 | Amber | Lit | CPU module #2 | Fatal CPU operating voltage |
| |
|
|
|
| alarm (upper limit) (VCCP) |
| |
CPU2 VttAlm 00 | Amber | Blink | CPU module #2 |
| ||
|
|
|
| (lower limit) |
| |
CPU2 VttAlm 02 | Amber | Lit | CPU module #2 | Fatal |
| |
|
|
|
| alarm (lower limit) |
| |
CPU2 VttAlm 07 | Amber | Blink | CPU module #2 |
| ||
|
|
|
| (upper limit) |
| |
CPU2 VttAlm 09 | Amber | Lit | CPU module #2 | Fatal |
| |
|
|
|
| alarm (upper limit) |
| |
|
|
|
|
|
| |
CPU20 TempAlm | Amber | Blink | CPU module #1 | CPU#1 temperature alarm | Check to see if dust is | |
00 |
|
|
| (lower limit) | accumulated on the | |
CPU20 TempAlm | Amber | Lit | CPU module #1 | Fatal CPU#1 temperature | internal fans. Check also | |
02 |
|
|
| alarm (lower limit) | if the fan cables are | |
CPU20 TempAlm | Amber | Blink | CPU module #1 | CPU#1 temperature alarm | connected securely. If | |
07 |
|
|
| (upper limit) | not solved by the above, | |
CPU20 TempAlm | Amber | Lit | CPU module #1 | Fatal CPU#1 temperature | contact your sales | |
09 |
|
|
| alarm (upper limit) | agent. | |
CPU21 TempAlm | Amber | Blink | CPU module #2 | CPU#2 temperature alarm |
| |
00 |
|
|
| (lower limit) |
| |
CPU21 TempAlm | Amber | Lit | CPU module #2 | Fatal CPU#2 temperature |
| |
02 |
|
|
| alarm (lower limit) |
| |
CPU21 TempAlm | Amber | Blink | CPU module #2 | CPU#2 temperature alarm |
| |
07 |
|
|
| (upper limit) |
| |
CPU21 TempAlm | Amber | Lit | CPU module #2 | Fatal CPU#2 temperature |
| |
09 |
|
|
| alarm (upper limit) |
| |
= D = |
|
|
|
|
| |
|
|
|
|
|
| |
DUMP Request! | Off |
| - | DUMP switch request | Contact your sales | |
|
|
|
|
| agent. | |
= F = |
|
|
|
|
| |
|
|
|
|
|
| |
FRB Processing | Off |
| - | During POST execution or OS | The server is operating | |
|
|
|
| start processing | normally. |