7-12 Troubleshooting

Indication

STATUS LED

Suspected

Explanation

Procedure

Color

State

module

 

 

 

CPU2 removed

Green

Blink

CPU module #2

The CPU module has come

Dismount and remount

 

 

 

 

off.

the PCI module. If not

 

 

 

 

 

solved by the above,

 

 

 

 

 

contact your sales

 

 

 

 

 

agent.

CPU2 Temp Alm

Amber

Blink

CPU module #2

Temperature alarm (lower

Check to see if dust is

00

 

 

 

limit)

accumulated on the

CPU2 Temp Alm

Amber

Lit

CPU module #2

Fatal temperature alarm (lower

internal fans. Check also

02

 

 

 

limit)

if the fan cables are

CPU2 Temp Alm

Amber

Blink

CPU module #2

Temperature alarm (upper

connected securely. If

07

 

 

 

limit)

not solved by the above,

CPU2 Temp Alm

Amber

Lit

CPU module #2

Fatal temperature alarm

contact your sales

09

 

 

 

(upper limit)

agent.

 

 

 

 

 

 

CPU2 VccpAlm 00

Amber

Blink

CPU module #2

CPU operating voltage alarm

Contact your sales

 

 

 

 

(lower limit) (VCCP)

agent.

CPU2 VccpAlm 02

Amber

Lit

CPU module #2

Fatal CPU operating voltage

 

 

 

 

 

alarm (lower limit) (VCCP)

 

CPU2 VccpAlm 07

Amber

Blink

CPU module #2

CPU operating voltage alarm

 

 

 

 

 

(upper limit) (VCCP)

 

CPU2 VccpAlm 09

Amber

Lit

CPU module #2

Fatal CPU operating voltage

 

 

 

 

 

alarm (upper limit) (VCCP)

 

CPU2 VttAlm 00

Amber

Blink

CPU module #2

1.25-V power voltage alarm

 

 

 

 

 

(lower limit)

 

CPU2 VttAlm 02

Amber

Lit

CPU module #2

Fatal 1.25-V power voltage

 

 

 

 

 

alarm (lower limit)

 

CPU2 VttAlm 07

Amber

Blink

CPU module #2

1.25-V power voltage alarm

 

 

 

 

 

(upper limit)

 

CPU2 VttAlm 09

Amber

Lit

CPU module #2

Fatal 1.25-V power voltage

 

 

 

 

 

alarm (upper limit)

 

 

 

 

 

 

 

CPU20 TempAlm

Amber

Blink

CPU module #1

CPU#1 temperature alarm

Check to see if dust is

00

 

 

 

(lower limit)

accumulated on the

CPU20 TempAlm

Amber

Lit

CPU module #1

Fatal CPU#1 temperature

internal fans. Check also

02

 

 

 

alarm (lower limit)

if the fan cables are

CPU20 TempAlm

Amber

Blink

CPU module #1

CPU#1 temperature alarm

connected securely. If

07

 

 

 

(upper limit)

not solved by the above,

CPU20 TempAlm

Amber

Lit

CPU module #1

Fatal CPU#1 temperature

contact your sales

09

 

 

 

alarm (upper limit)

agent.

CPU21 TempAlm

Amber

Blink

CPU module #2

CPU#2 temperature alarm

 

00

 

 

 

(lower limit)

 

CPU21 TempAlm

Amber

Lit

CPU module #2

Fatal CPU#2 temperature

 

02

 

 

 

alarm (lower limit)

 

CPU21 TempAlm

Amber

Blink

CPU module #2

CPU#2 temperature alarm

 

07

 

 

 

(upper limit)

 

CPU21 TempAlm

Amber

Lit

CPU module #2

Fatal CPU#2 temperature

 

09

 

 

 

alarm (upper limit)

 

= D =

 

 

 

 

 

 

 

 

 

 

 

DUMP Request!

Off

 

-

DUMP switch request

Contact your sales

 

 

 

 

 

agent.

= F =

 

 

 

 

 

 

 

 

 

 

 

FRB Processing

Off

 

-

During POST execution or OS

The server is operating

 

 

 

 

start processing

normally.