System Configuration
TIPS:
A message informing you of the completion of CMOS clear and prompting you to clear CMOS will appear for 10 seconds. Note that even if you do not do anything, the process goes on and the server will be rebooted automatically.
8.If the message [Non volatile memory cleared] appears after rebooting and during POST, turn off the power by pressing the POWER switch and unplug the both power cords.
Non volatile memory cleared:
This message indicates that CMOS is cleared properly.
IMPORTANT:
If the message [Non volatile memory cleared] appears at normal startup, the jumper switch is set for clearing CMOS. Change back the jumper switch setting.
9.Remove the PCI Module #1 from NEC Express5800/ft series (see “Removing PCI Module” on page
10.Reset the jumper switch setting.
Remove the clips from the jumper pins
TIPS: If you place clips on other pins, the server may malfunction.
11.Mount the PCI Module #1 again to NEC Express5800/ft series (see “Installing PCI Module” on page
12.Likewise, mount the PCI Module #2 to NEC Express5800/ft series and plug the power cord to the AC inlet A (for Group2).