Connect from the Management PC Linked through LAN
On the management PC that is linked through LAN, perform the steps below:
1.Start the management PC where NEC MWA is installed. From the Start menu, select [Program] → [NEC MWA] → [MWA].
When NEC MWA starts, the initial screen “Remote Control Manager” will appear.
2.Insert a formatted 1.44MB floppy disk into the drive.
3.From NEC MWA’s [File] menu, select [Configuration] command to open [Configuration] dialog box.
4.Select [New] to display the [Select a model] dialog box.
5.Check [Write to FD] and select an applicable model to open [Configuration for ft Server] dialog box.
Ex) The model name is printed on the front cover like “NEC Express5800/320Lc,” or “NEC
6.On the [Configuration for ft Server] dialog box, specify/register configuration information including the names of computers to be managed, and then write the information to FD as the following filename:
<Filename>
CSL_LESS.CFG
The setting items of the server are as follows: Computer Name (The managed server name. Arbitrary) IP address
Subnet mask Default gateway
Primary contact (Management PC’s IP address)
7.
8.When the [Property] dialog box appears, specify the items as follows:
<[ID] page> |
|
Connection mode: | LAN |
<[Alert notification] page>
Uncheck [Use Default Settings] and check [Reset] of [Activate].