reason, consult your sales agent. It is possible to perform reintegration forcefully.
Source: | srabid |
ID: | 16395 |
Description: | x is now STATE_BROKEN / REASON_BELLOW_MTBF (“x” |
| is a device number.) |
An unavailable disk is displayed on Disk Management:
→Follow the instructions on the table below:
Disk status |
| Description |
| Action | |
| [Foreign] | appears | when | [To use the disk’s data] | |
| loading | a dynamic disk | Referring to Chapter 3 “Windows | ||
| which has been used in a | Setup and Operation”, import the disk. | |||
| different system. |
| [To change the disk to an available | ||
|
|
|
|
| |
|
|
|
|
| disk] |
|
|
|
|
| To use this disk, it needs to be |
|
|
|
|
| initialized. It will become available |
|
|
|
|
| after initialization. |
|
|
|
|
| <Note> |
|
|
|
|
| Initialization erases all data on the disk. |
|
|
|
|
| If there is important data, back up data |
|
|
|
|
| before initialization. |
| [Missing] | appears | when a | If there is a volume on the missing | |
| dynamic disk is damaged or | disk, break the mirror on that disk. | |||
| removed. |
|
| Then | |
|
|
|
|
| perform [Remove disk]. |
|
|
|
|
| |
| [Not | Initialized] | appears | ||
| when the disk is not signed. | [Initialize Disk]. The disk will become | |||
|
|
|
|
| available. |
|
|
|
|
|
|
Primary PCI module’s status LED2 and DISK ACCESS LED illuminate amber after startup:
Is the mirroring of the hard disks broken?
→See [Disk Management] and if the mirror is broken, reconfigure it.
For mirroring configuration, see “DISK OPERATIONS” in Chapter 3 “Windows Setup Operation.”
Other than disk failure, the mirror may be removed at startup after the following operations:
•Started the server after shutdown with the PCI module in simplex mode
•Started NEC Express5800/ft series when the BMC status LED was blinking The duplication process of Baseboard Management Controller (BMC) is executed