The table below lists how selections for "AC LINK" determine the power status of the server when the power supply to the server restarts.
State before powered off |
| Parameter |
| |
Stay Off | Last State | Power On | ||
| ||||
In service | Off | On | On | |
Out of service (DC power: Off) | Off | Off | On | |
Forced shutdown * | Off | Off | On |
*Pressing the POWER switch for over four seconds shuts down the power to the server.
Thermal Sensor
Select "Thermal Sensor" on the System Hardware menu and press Enter to display the following screen.
|
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
| ||
| Thermal Sensor: |
|
| |||
|
|
|
|
| ||
| Upper Limit: |
|
| |||
|
|
| ||||
| Lower Limit: |
|
| |||
|
|
|
|
| ||
|
|
|
|
|
|
|
F1 Help |
|
|
|
|
| Select Item | Change Values | F9 Setup Defaults | ||
Esc Exit |
|
|
|
|
| Select Menu | Enter Select | F10 Save Changes & Exit | ||
|
|
|
|
See the table below for setup options on the screen.
Option | Parameter | Description | Your Setting | |
Thermal | [Enabled] | Enable or disable the thermal sensor |
|
|
Sensor | Disabled | monitoring feature. |
|
|
Upper Limit | 7 - [48] - 80 | Specify the upper limit temperature for |
|
|
|
|
|
| |
|
| keys to specify a value by adding a number |
|
|
|
| greater than 7 to the value specified for |
|
|
|
| Lower Limit. |
|
|
Lower Limit | 0 - [5] - 73 | Specify the lower limit temperature for |
|
|
|
|
|
| |
|
| 4 degrees or lower. Use + and/or - keys to |
|
|
|
| specify a value by deducting a number |
|
|
|
| greater than 7 to the value specified for |
|
|
|
| Upper Limit. |
|
|
|
| [ | ]: |
|