Installing and Using Utilities 5-57

Firmware Update

NEC Express5800/ft series can update firmware (including BIOS) if some hardware components operate in the online state (in which the system continues the operation but the component trying to update firmware or BIOS is stopped).

To update firmware with NEC ESMPRO Manager, use the [Update] tree of the component in the data viewer. Open the tree of the component for which firmware is updated and select the [Update] tree.

To update the firmware of a component with the ft server utility, use the utility screen of the component.

To update the firmware of a component, the firmware image file of the firmware for update must previously be stored in the managed server. On the firmware update screen, specify the path to the firmware image file for update.

The table below shows the potential cases in which the firmware of a component is to be updated.

Component

 

Firmware update

Remote

Local

 

CPU Module

When BIOS must be updated to

When BIOS must be updated to new

 

new one.

one.

 

Executable in any of the

Executable in the following module

 

following module states (this can

state:

 

be viewed on manager screen):

When the status LED 1 is red and the

 

 

 

 

Removed

 

status LED 2 is off

 

Broken or forced stop

Only the status LED 1 illuminates red

 

No fault found by diagnosis

 

when the module is in one of the

 

 

 

 

To update the module under

following states:

 

operation, bring down the

Removed

 

module before the update.

Broken or forced stop

 

 

 

No fault found by diagnosis

 

 

 

 

(Firmware Update Complete)

 

 

 

To update the module under operation,

 

 

 

bring down the module before the

 

 

 

update.

Remote: Executable from remote management PC by using NEC ESMPRO Manager

Local: Executable on local server by using ft server utility

–: Not support