7-16

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

On-screen error message

Cause

Action

 

0B29

Unsupported Processor

The processor (CPU) not

Install the CPU appropriate to

 

 

detected on Processor 2

supported by this server is

the server.

 

 

 

installed in Processor 2.

 

 

 

0B30

CPU FAN #1 Alarm

Dusts are clogged in fan.

Replace the fan.

 

 

occurred

Fan is faulty.

Replace the CPU module

 

0B31

CPU FAN #2 Alarm

CPU module board is faulty.

 

board.

 

 

occurred

 

 

Connect fan cable properly.

 

0B32

CPU FAN #3 Alarm

Dusts are clogged in fan.

Replace the fan.

 

 

occurred

Fan is faulty.

Replace the CPU module

 

 

 

CPU module board is faulty.

 

board.

 

 

 

 

 

Connect fan cable properly.

 

0B40

Invalid System

Configuration error in

Reset the setting by

 

 

Configuration Data

 

SETUP.

 

selecting [Yes] at [Reset

 

 

 

CPU/PCI module board is

 

Configuration Data]

 

 

 

 

faulty.

Replace the CPU/PCI

 

 

 

 

 

 

module board.

 

0B41

System Configuration

Configuration error in

Reset the setting by

 

 

Data Read error

 

SETUP.

 

selecting [Yes] at [Reset

 

 

 

CPU/PCI module board is

 

Configuration Data]

 

 

 

 

faulty.

Replace the CPU/PCI

 

 

 

 

 

 

module board.

 

0B42

Resource Conflict

Configuration error in SETUP.

Correct device configuration in

 

 

 

 

 

SETUP

 

0B43

Warning: IRQ not

Configuration error in SETUP.

Correct settings in SETUP

 

 

configured

 

 

 

 

 

0B44

Expansion Rom not

Configuration error in SETUP.

In SETUP, disable

 

 

initialized

 

 

decompression of expansion

 

 

 

 

 

ROM on unnecessary optional

 

 

 

 

 

PCI cards.

 

0B45

System Configuration

Configuration error in

Reset the setting by

 

 

Data Write error

 

SETUP.

 

selecting [Yes] at [Reset

 

 

 

CPU/PCI module board is

 

Configuration Data]

 

 

 

 

faulty.

Replace the CPU/PCI

 

 

 

 

 

 

module board.

 

0B47

Missing date and time

The date and time are

Restart the system.

 

 

synchronization

incorrect due to a

Re-set the date and time in

 

 

 

communication error between

 

SETUP.

 

 

 

BMCs.

If the error persists, replace the

 

 

 

 

 

PCI module board.

 

0B49

BMC Issued Reset

System cannot be reset by

Replace PCI module board.

 

 

Command, but failed

 

BMC’s reset command.

 

 

 

 

System Reset

 

 

 

 

 

0B6E DIMMs are installed out

DIMM is faulty.

Replace DIMM.

 

 

of order

 

 

 

 

 

0B70 The error occurred

SMBus device is faulty.

Replace the CPU/PCI module

 

 

during temperature

SMBus is faulty.

or back panel board.

 

 

sensor reading