System Configuration 4-21

System Hardware

Move the cursor onto "System Hardware" to display the System Hardware menu.

To make a selection for "Thermal Sensor", "Wake On Event", and "Console Redirection", first select a desired option and press Enter to display its submenu.

See the table below for setup options on the screen.

Option

Parameter

Description

Your Setting

AC LINK

Stay Off

Specify the AC LINK feature by selecting the

 

 

 

[Last State]

status of the power supply unit of the server

 

 

 

Power On

when the AC power supply restarts. (See the

 

 

 

 

table on the next page for details.) Do not

 

 

 

 

select the parameters other than "Stay Off"

 

 

 

 

when "Enabled" is selected for "Wake On

 

 

 

 

Lan."

 

 

Waiting time

[0], 10~3600

Set maximum waiting time in second for

 

 

for AC-LINK

 

AC-LINK. If either of ACs is not supplied in

 

 

 

 

time, the system will be turned on as simplex

 

 

 

 

config. Value 0 means the system waits

 

 

 

 

eternally.

 

 

 

 

Range [0 or 10-3600sec.]

 

 

Error Log

Enter

Press Enter to initialize the error log. The

 

 

Initialization

 

message "Error Log Cleared" appears upon

 

 

 

 

successful completion. If failed, the message

 

 

 

 

"Error Log Not Cleared!" appears.

 

 

 

 

[

]: Factory-set

 

IMPORTANT: It is recommended that “Waiting time for AC-LINK” be 3600 when you use UPSs in the redundant configuration.