Connect from the Management PC Directly Linked (through Serial port B)
On the management PC that is linked directly to Serial port B of the main unit, perform the steps below:
1.Start the management PC where NEC MWA is installed. From the Start menu, select [Program] → [NEC MWA] → [MWA].
When NEC MWA starts, the initial screen “Remote Control Manager” will appear.
2.Select [Environment] – [Direct Connection Setting] from the [File] menu of NEC MWA to display the [Direct Connection] dialog box. Configure the following settings:
<Direct Connection>
Port No.: | COM port on the management PC to be connected |
Baud Rate: | 19200 |
Flow Control: | None |
3.From MWA’s [File] menu, select [Configuration] command to open [Configuration] dialog box.
4.Select [New] to display [Select a model] dialog box.
5.Check [Write to FD] and select an applicable model to open [Configuration for ft Server] dialog box.
Ex) The model name is printed on the front cover like “NEC Express5800/320Lc,” or “NEC
6.On the [Configuration for ft Server] dialog box, specify/register configuration information including the names of computers to be managed, and then write the information to FD as the following filename:
<Filename>
CSL_LESS.CFG
7.
8.When the [Property] dialog box appears, specify the items as follows:
<[ID] page> |
|
Connection mode: | COM |
COM: | Direct (cross cable) |
9.
After checking to see if the server window is open on [MWA Remote Console], click the [Connect] button.
10.Hook up the management PC directly to Serial port B of the computer to be managed.
11.Insert NEC EXPRESSBUILDER