General Description
To power on NEC Express5800/ft series, press the POWER switch located on the front panel.
Follow the steps below to turn on the power. (A
1.Power on the display unit and other peripheral devices connected to the server.
TIPS:
If the power cord is connected to a power controller like a UPS, make sure that it is powered on.
When NEC Express5800/ft series is powered on, BMCs between the two PCI modules are synchronized. (The BMC status LED on secondary module blinks.) See Chapter 2 “LEDs” for details of the BMC status LED.
2.Detach the front bezel (or open it in the case of a tower model).
3.Confirm that the BMC status LED on both PCI modules are off and press the POWER switch which illuminates green and located on the front panel.
After a while, the "NEC" logo will appear on the screen.
POWER switches* (LEDs) *You can only use a power switch whose LED is on.
IMPORTANT:
Do not turn off the power before the "NEC" logo appears.
When powering on, make sure that the BMC status LED on the both PCI modules are off and then press the power switch.
While the "NEC" logo is displayed on the screen, NEC Express5800/ft series is performing a
TIPS: If the server finds errors during POST, it will interrupt POST and display the error message. See Chapter 7.