NEC NWA-008869-001 manual Switch Name, Setting, Function, Check, Number, Position

Models: NWA-008869-001

1 180
Download 180 pages 45.76 Kb
Page 39
Image 39

CHAPTER 2 INSTALLATION

INSTALLATION PROCEDURE

Switch Settings

CAUTION

When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot.

SWITCH NAME

SWITCH

SETTING

FUNCTION

CHECK

NUMBER

POSITION

 

 

 

 

 

SW3 (Rotary SW)

 

0

On Line

 

 

 

(Call processing is in progress)

 

 

 

 

 

0

 

 

 

 

 

2

Off Line (Call processing is stopped)

 

 

 

 

 

 

• I/O port: As per CM40 Y=08

 

 

 

 

 

 

 

 

 

 

 

 

3

Off Line (Call processing is stopped)

 

 

 

• I/O port: 9600 bps (Fixed)

 

NOTE 1

 

 

 

 

 

 

 

 

5

Off Line (Call processing is stopped)

 

 

 

 

 

 

NOTE 2

• I/O port: 9600 bps

 

 

 

 

 

 

 

0-F

6

Off Line (Call processing is stopped)

 

 

NOTE 2

• I/O port: 19200 bps

 

 

 

 

7Off Line (Call processing is stopped) NOTE 2 • I/O port: 38400 bps

8Off Line (Call processing is stopped) NOTE 2 • I/O port: 57600 bps

BFor clearing the office data

CFor setting the resident system program

1, 4, 9

Not used

A, D-F

 

NOTE 1: Set the groove on the switch to the desired position.

NOTE 2: Only when executing “MP Program Download” using MATWorX, set the SW3 to 5-8.

Continued on next page

– 29 –

NWA-008869-001 Rev.1.0

 

atch2001.fm

Page 39
Image 39
NEC NWA-008869-001 manual Switch Name, Setting, Function, Check, Number, Position