CHAPTER 2 INSTALLATION
INSTALLATION PROCEDURE
Switch Settings
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot.
SWITCH NAME | SWITCH | SETTING | FUNCTION | CHECK |
NUMBER | POSITION | |||
|
|
|
|
|
SW3 (Rotary SW) |
| 0 | On Line |
|
|
| (Call processing is in progress) |
| |
|
|
|
| |
0 |
|
|
|
|
| 2 | Off Line (Call processing is stopped) |
| |
|
|
| ||
|
| • I/O port: As per CM40 Y=08 |
| |
|
|
|
| |
|
|
|
|
|
|
| 3 | Off Line (Call processing is stopped) |
|
|
| • I/O port: 9600 bps (Fixed) |
| |
NOTE 1 |
|
|
| |
|
|
|
| |
| 5 | Off Line (Call processing is stopped) |
| |
|
|
| ||
|
| NOTE 2 | • I/O port: 9600 bps |
|
|
|
|
|
|
| 6 | Off Line (Call processing is stopped) |
| |
| NOTE 2 | • I/O port: 19200 bps |
| |
|
|
|
7Off Line (Call processing is stopped) NOTE 2 • I/O port: 38400 bps
8Off Line (Call processing is stopped) NOTE 2 • I/O port: 57600 bps
BFor clearing the office data
CFor setting the resident system program
1, 4, 9 | Not used |
A, |
|
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: Only when executing “MP Program Download” using MATWorX, set the SW3 to
Continued on next page
– 29 – | |
| atch2001.fm |