CHAPTER 4 INITIALIZATION
SETTING UP THE WAN PRIVATE LINE (T1)
SETTING UP THE WAN PRIVATE LINE (T1)
You can connect the
(1)Set line attributes for a T1 Line
(2)Shutting down and restarting the interface for the settings to take effect
(3)Save setting data
(4)Check the status of interface
Setting line attributes for a T1 Line
Set the line attributes of a T1 line if necessary.
The line attributes you can set are a type (default: b8zs) of line code (b8zs/ami), lbo (default: 0 [db]/0 to
132 [feet]), and the number of time slots for T1 (default: 12 time slots). If you use default settings, you do not need to perform these settings. To set line attributes of a T1 line, use the Serial0 in device config mode.
For details, refer to “Router Command Reference Manual”.
ix1000 − 01 # enable − config Enter
ix1000 − 01 (config) # device Serial0 Enter ix1000 − 01 (config − Serial0) #
NOTE: If you change a line attribute of a T1 line to another, you must shut down and restart the inter- face for the change to take effect.
– 104 – | |
| atch4001.fm |