Paradyne 6800 manual Total seconds, Errored seconds, Total bits, Errored bits

Models: 6800

1 237
Download 237 pages 50.18 Kb
Page 137
Image 137

COMSPHERE 6800 Series Network Management System

Total seconds

The total number of seconds that has elapsed.

Errored seconds

The number of errored seconds.

Total bits

The number of bits that have been transmitted thus far.

Errored bits

The number of bits that have been received in error.

Figure 2-32 is sample of the Digital Test results form for 3600 Series DSUs and DBMs.

Figure 2-32. Digital Test Results Form for 3600 Series DSUs/DBMs

This results form lists device information for each control and tributary device specified, indicates whether the results are complete or intermediate, and displays the following fields:

Requested duration of test in seconds

As specified in the input form.

Requested port number

As specified in the input form.

2-114

January 1997

6800-A2-GB31-20

Page 137
Image 137
Paradyne 6800 manual Total seconds, Errored seconds, Total bits, Errored bits, Requested duration of test in seconds