COMSPHERE 6800 Series Network Management System

Display Thresholds (dst)

Use the dst command to display the current fault threshold set on COMSPHERE 3400/4400 Series devices which determine when alerts should be generated. Threshold (TH) alerts are generated when the line parameters exceed the thresholds defined by the Change Thresholds (cht) command.

For most commands, NMS enables you to specify the destination for the command's results and schedule its execution. If the last page of the input form cannot accommodate the Destination for results and Schedule execution fields, an additional page is provided. For a complete description of these fields, refer to Chapter 1, Introduction.

Access Level: Help Desk, Data Technician, Manager, System Administrator

Abbreviation: dst

Restrictions: None

Routine:Yes

Schedule:Yes

Related Commands: Change Thresholds (cht)

Display Thresholds Input Form

This input form contains the following field:

Device(s) (Required field)

Enter the device(s) for which thresholds are to be displayed. One or more devices may be specified. Standard addressing format applies to the input. For information on device addressing, refer to Appendix D of the COMSPHERE 6800 Series Network Management System User's/System Administrator's Guide.

Display Thresholds Results Form

The Display Thresholds results form lists device information for each device specified, and displays the threshold information applicable to the device.

This results form contains the following fields:

Receive level (high)

Displays the high received signal level that causes a device to report a threshold alert.

Receive level (low)

Displays the low received signal level that causes a device to report a threshold alert.

Signal-to-noise ratio

Displays a signal-to-noise ratio that, when exceeded, triggers a threshold alert.

2-142

January 1997

6800-A2-GB31-20

Page 165
Image 165
Paradyne 6800 manual Display Thresholds dst, Display Thresholds Input Form, Display Thresholds Results Form