Modem/DSU Commands

Transmit Test Pattern (ttp)

(Disruptive)

Use the ttp command to turn on or off the test pattern generator in a DATAPHONE II or COMSPHERE 3600 Series DSU. If the generator is turned on, either at a control or tributary DSU, a test pattern is sent over the transmission path to the corresponding DSU.

For most commands, NMS enables you to specify the destination for the command's results and schedule its execution. If the last page of the input form cannot accommodate the Destination for results and Schedule execution fields, an additional page is provided. For a complete description of these fields, refer to Chapter 1, Introduction.

Access Level:

Data Technician, Manager, System Administrator

Abbreviation:

Abbreviation: ttp

Restrictions:

For a DATAPHONE II DSU to receive the test pattern successfully, a DSU

 

must be manually addressed at the Shared Diagnostic Unit and the test

 

pattern generator must be turned on. This allows end-to-end tests to be

 

conducted to isolate marginal trouble in either the send or receive direction

 

of the digital path. The results of this test are displayed on the Shared

 

Diagnostic Unit's liquid crystal display.

 

For a 3600 Series DSU or an associated V.32 DBM to receive the test

 

pattern successfully, the remote DSU or DBM must be in digital loopback.

 

This directs the bit pattern back to the originating device where it is

 

checked for errors. These errors are displayed on the front panel of the

 

DSU. The results of this test can be displayed at the NMS by executing the

 

Modem Bit Error Rate (mbert) command.

Routine:

Yes

Schedule:

Yes

Related Commands:

None

Transmit Test Pattern Input Form

This input form contains the following fields:

Device(s) (Required field)

Enter the device(s) whose test pattern generator will be turned on or off. One or more devices may be specified. Standard addressing format applies to the input. For information on device addressing, refer to Appendix D of the COMSPHERE 6800 Series Network Management System User's/System Administrator's Guide.

Device state (Required field)

Enter transmit to transmit the test pattern. The test pattern will be transmitted until you execute the ttp command again using the release option or until you execute the Abort (abort) command.

Enter release to stop transmitting.

6800-A2-GB31-20

January 1997

2-207

Page 230
Image 230
Paradyne 6800 manual Transmit Test Pattern ttp, Transmit Test Pattern Input Form