COMSPHERE 6800 Series Network Management System

Abort type (Required field)

Enter the type of abort:

subnetwork

All tests running on the specified device and all of its downstream devices are aborted.

selective

All tests running on the specified device are aborted; tests running on downstream devices are not affected. This option can be selected only for COMSPHERE devices in the Advanced Diagnostic protocol (ADp) mode.

A pop-up menu is available listing valid selections.

Abort Command Results Form

This results form displays device information for each device specified by the user in the input form, and the type of abort (subnetwork or selective) that was sent.

NOTE

A results form that reports the abort command as successfully executed indicates only that the device acknowledged its receipt of the command. It does not guarantee that the tests or any commands in progress at the time the command was issued were actually aborted. If a test has already completed at the device before the abort command arrives, the NMS will report both the results of the completed test and that the abort was successfully executed (command receipt acknowledged by the device).

2-4

January 1997

6800-A2-GB31-20

Page 27
Image 27
Paradyne 6800 manual Abort Command Results Form, Abort type Required field, Subnetwork, Selective