Roland Vs-880 Operating the VS-880 from another device MMC, Settings for the master VS-880

Models: Vs-880

1 154
Download 154 pages 30.99 Kb
Page 122
Image 122
Operating the VS-880 from another device (MMC)

Chapter 11 Taking advantage of the VS-880 (ideas and examples)

Operating the VS-880 from another device (MMC)

The VS-880 supports MMC. This means that when two VS-880 units are synchronized or when a VS-880 is used in conjunction with an MMC-supporting MIDI sequencer etc., operations such as song playback, stop and fast-forward can be performed by operating only the master device.

*Depending on the MIDI device that you are using, some devices may not support the MMC functionality of the VS-880. In this case, the VS-880 cannot be operated as explained in this ownerÕs manual. The MMC functionality supported by the VS-880 is described in detail in the separately sold MIDI Implementation. If you wish to purchase a copy, contact a nearby Roland service center or your dealer.

<About MMC >

MMC is an acronym for ÒMIDI Machine Control.Ó This is a rule that defines how MIDI system exclusive messages can be used to control multiple recording devices from a single device. The VS-880 supports MMC. In addition to song playback, stop and fast-forward, you can also select the tracks for recording, etc.

Synchronizing the operation of two VS-880 units

Here we will explain how the operation of two VS-880 units can be synchronized. One VS-880 will be the master, and the other VS-880 will be the slave. Make connections as follows.

MASTER OUT L, R

MIDI IN■Synchronizing the operation of two VS-880 units

Settings for the master VS-880 INPUT 1, 2

MIDI OUT

SLAVE

MASTER

Settings for the master VS-880

1.Press [SYSTEM] several times until “SYS MIDI PRM ?” appears.

2.Press [YES].

3.The display will indicate “SYS MID:DeviceID=”. Make sure that the device ID number is “17”.

DeviceID (Device ID)

This sets the Device ID number (1Ð32) that is used when exchanging exclusive messages (mixer parameters) with an external MIDI device. Exclusive messages can be transmitted and received between devices which have the same Device ID number setting.

4.Press PARAMETER [ DeviceID (Device ID)Manual background ].

5.The display will indicate “SYS MID:MIDIThr=”. For this example, select “Out” so that MTC can be transmitted.

MIDIThr (MIDI thru switch)

This selects the function of the MIDI OUT/THRU connector. With the factory settings, this is set to ÒOut.Ó

Out: The connector will transmit MIDI messages from the VS-880. Select this when you want to transmit metronome Note messages or mixer parameter settings (control change mes- sages or exclusive messages).

Thru: MIDI messages received at the MIDI IN connector will be retransmitted from the con- nector without change.

122

Page 122
Image 122
Roland Vs-880 Operating the VS-880 from another device MMC, Synchronizing the operation of two VS-880 units