Datasheet |
|
|
|
|
|
4.5.8 | Mode Control/Status |
|
|
|
|
| Index (In Decimal): 17 | Size: | 16 bits |
| |
|
|
|
|
|
|
BITS | DESCRIPTION |
|
| TYPE | DEFAULT |
|
|
|
|
|
|
15:14 | RESERVED |
|
| RO | - |
|
|
|
|
|
|
13 | EDPWRDOWN |
|
| R/W | 0b |
| Enable the Energy Detect |
|
|
|
|
| 0=Energy Detect |
|
|
|
|
| 1=Energy Detect |
|
|
|
|
|
|
|
|
|
|
12:2 | RESERVED |
|
| RO | - |
|
|
|
|
|
|
1 | ENERGYON |
|
| RO | 1b |
| Indicates whether energy is detected. This bit goes to a “0” if no valid |
|
| ||
| energy is detected within 256ms. Reset to “1” by hardware reset, unaffected |
|
| ||
| by SW reset. |
|
|
|
|
|
|
|
|
|
|
0 | RESERVED |
|
| R/W | 0b |
|
|
|
|
|
|
SMSC LAN9420/LAN9420i | 143 | Revision 1.22 |
| DATASHEET |
|