Datasheet
5.3.2D3 - Enabled for Wake Up Packet DetectionTable 5.2 D3 - Enabled for Wake Up Packet Detection - Supply and Current (Typical)
PARAMETER | TYPICAL | UNIT | |
(@ 3.3V) | |||
|
| ||
|
|
| |
|
| ||
|
|
| |
Supply current (VDD33IO, VDD33BIAS, VDD33A) | 76 | mA | |
|
|
| |
Power Dissipation (Device Only) | 252 | mW | |
|
|
| |
Power Dissipation (Device and Ethernet components) | 400 | mW | |
|
|
| |
Ambient Operating Temperature in Still Air (TA) | 25 | oC | |
|
| ||
|
|
| |
Supply current (VDD33IO, VDD33BIAS, VDD33A) | 40 | mA | |
|
|
| |
Power Dissipation (Device Only) | 131 | mW | |
|
|
| |
Power Dissipation (Device and Ethernet components) | 502 | mW | |
|
|
| |
Ambient Operating Temperature in Still Air (TA) | 25 | oC |
Table 5.3 D3 - Enabled for Link Status Change Detection - Supply and Current (Typical)
PARAMETER | TYPICAL | UNIT | |
(@ 3.3V) | |||
|
| ||
|
|
| |
|
| ||
|
|
| |
Supply current (VDD33IO, VDD33BIAS, VDD33A) | 21 | mA | |
|
|
| |
Power Dissipation (Device Only) | 70 | mW | |
|
|
| |
Power Dissipation (Device and Ethernet components) | 70 | mW | |
|
|
| |
Ambient Operating Temperature in Still Air (TA) | 25 | oC | |
|
| ||
|
|
| |
Supply current (VDD33IO, VDD33BIAS, VDD33A) | 21 | mA | |
|
|
| |
Power Dissipation (Device Only) | 70 | mW | |
|
|
| |
Power Dissipation (Device and Ethernet components) | 70 | mW | |
|
|
| |
Ambient Operating Temperature in Still Air (TA) | 25 | oC |
SMSC LAN9420/LAN9420i | 157 | Revision 1.22 |
| DATASHEET |
|