Changing the Settings
Item | Remarks | Value | Default |
|
|
|
|
|
|
|
|
Spool | Activation of spool function. | Disk/Memory/Off | Disk |
| Select from Disk, Memory, and Off. |
|
|
| If Disk is selected but not |
|
|
| recognized, Memory will be used. |
|
|
|
|
|
|
Max Spool Size | The maximum receive buffer size | 1024 KB | |
| during spooling. |
|
|
| Can be set in 256 KB increments. |
|
|
|
|
|
|
Max Receive | The maximum receive buffer size | 256 KB | |
Buffer Size | during |
|
|
| Can be set in 32 KB increments. |
|
|
|
|
|
|
JCL | Activation of JCL | On/Off | On |
|
|
|
|
Print Mode | Set the printer language. | AUTO/PS*/PCL/ | AUTO |
|
| TIFF |
|
|
|
|
|
Auto Master | Activation of the automatic browse | On/Off | On |
Mode | master feature. |
|
|
| Not available when WINS server is |
|
|
| designated. |
|
|
|
|
|
|
Encrypt | Activation of the encrypt password | On/Off | On |
Password | feature. |
|
|
|
|
|
|
Time Zone | Set the time zone in units of | 0 (GMT – | |
| minutes. | minutes | Greenwich Mean |
|
|
| Time) |
|
|
|
|
Daylight Saving | Set the period of summer time. Set | — | |
| the time, date, and month for both |
| |
| the start date and end date of | hhddmm) |
|
| summer time. For example “1- |
|
|
|
|
| |
| system clock by one hour at 1 a.m. |
|
|
| on 28th March, and go back one |
|
|
| hour at 2 a.m. on 31st October. |
|
|
|
|
|
|
Maximum | Maximum connections of the | 5 | |
Sessions | machine. |
|
|
|
|
|
|
Unicode Support | Enable the use of Unicode. If this | Enable/Disable | Disable |
| is disabled then the local code, |
|
|
| such as |
|
|
|
|
|
|
DHCP | Activation of DHCP. | Yes/No | Yes |
|
|
|
|
Get WINS DHCP | Activation of WINS DHCP. | On/Off | On |
|
|
|
|
IP Address | Set the IP address. | — | 0.0.0.0 |
|
|
|
|
Subnet Mask | Set the subnet mask. | — | 0.0.0.0 |
|
|
|
|
Gateway | Set the gateway address. | — | 0.0.0.0 |
Address |
|
|
|
|
|
|
|
Xerox CopyCentre/WorkCentre/WorkCentre Pro 123/128 System Administration Guide | 77 |