| Chapter 6 |
$aaSiØ |
|
Name | Read Digital filter scale |
Description | Read the filter seconds to start to measure the input |
| signal. |
Syntax | $aaSiØ(cr) |
| $ is a delimiter character. |
| aa (range |
| address of the |
| Si identifies the I/O slot which is to be accessed. |
| Ø is the command for reading digital filter scale. |
| (cr) is the terminating character, carriage return (0Dh) |
Response | !aa(data)(cr) if the command is valid. |
| ?aa(cr) if an invalid operation was entered. |
| There is no response if the module detects a syntax error or |
| communication error or if the specified address does not |
| exists. |
| ! delimiter character indicating a valid command was |
| received. |
| ? delimiter character indicating the command was |
| invalid. |
| aa (range |
| address of an |
| (data) represents filter secends from 8 µs~65000 µs. Be |
| aware that (data) has 5 characters. |
| (cr) is the terminating character, carriage return (0Dh) |