Chapter 6
$aaSiCj5s
Name | Set Counter Start/Stop |
Description Request the addressed counter/frequency module to | |
| start or stop the counting. |
Syntax | $aaSiCj5s(cr) |
| $ is a delimiter character. |
| aa (range |
| address of the |
| SiCj identifies the I/O slot i and the channel j of the |
| module you want to set. |
| 5 is the command for setting counter Start/Stop. |
| s represents start/stop command. |
| s=0 indicate stop counter. |
| s=1 indicate start counter. |
| (cr) is the terminating character, carriage return (0Dh) |
Response | !aa(cr) if the command is valid. |
| ?aa(cr) if an invalid operation was entered. |
There is no response if the module detects a syntax error or communication error or if the specified address does not exists.
! delimiter character indicating a valid command was received.
? delimiter character indicating the command was invalid.
aa (range
(cr) is the terminating character, carriage return (0Dh)