Chapter 4 Installation and Setup

Figure 4.5 Avaya P133GT2 Module

Front-Panel Pushbuttons

Two pushbuttons, Left and Right, are used to select the function to be shown simultaneously on all Port LEDs. The current function selected is indicated by a lit Function LED.

When you press both Left and Right pushbuttons simultaneously for 1.5 seconds then the module is reset. The LEDs are described on Page 12.

Configuration Symbol

The Configuration Symbol (C/S) of the P130 module is the hardware version number and can be found either via the MultiService Network Manager application, via the CLI, or on a label on the module.

Serial Number

The P130 Serial Number is a unique number allocated to a specific P130 module. This 7-digits number is shown on a label on the module and can be found using the MIB item - genGroupSerialNumber.

Power Supply

The P130 110/220 VAC power inlet is at the back of the box.

P130/P330/P120 Back-up Power Supply (BUPS)

The P133G2 and P134G2 modules have a Back-Up Power Supply (Female D-Type connector) connector on their back panels. You can use the same BUPS unit for the P130, P330 and P120 switches.

The BUPS input is 150 W @ 5 V DC and operates in load power sharing mode with the internal P130 module power supply (See: P133G2/P134G2 AC Back Panels on Page 13).

Avaya P130 User’s Guide

19

Page 33
Image 33
Avaya P130 manual Front-Panel Pushbuttons, Configuration Symbol, Serial Number, Power Supply