3

Sending Documents

Set

Set

6 Press [] or [] to display <ON> press [Set].

If you select ‘OFF’, proceed to step 8. In this case, redialing is not attempted after the first dialing attempt fails.

7 Press [] or [] to display the desired Auto Redial setting press [Set].

The AUTO REDIAL menu includes the following items:

Setting

Description

 

 

1. REDIAL TIMES

Sets the number of times the machine attempts to dial a

 

number before it cancels the transaction automatically.

 

Even if the machine is set to redial several times, it will redial

 

only once if there is no dial tone or ring back tone during the first

 

attempt.

 

You can set the machine to redial between 01 to 10 times.

 

(Default setting: ‘02TIMES’*)

 

 

2. REDIAL INTERVAL

Sets the length of time the machine waits between redialing

 

attempts.

 

You can set the time interval between 02 to 99 minutes.

 

(Default setting: ‘02MIN’.*)

 

 

3. TX ERROR RESEND

Selects whether to perform automatic redialing when a

 

transmission error occurs.

ON*

The machine automatically redials the number after a

 

transmission error occurs, and enables you to customize the

 

redial operation.

ERROR & 1ST

The machine redials the number and resends the document

PAGE*

from the page where the error occurred, as well as the first

 

page of the document.

ERROR PAGE

The machine redials the number and resends the failed pages

 

only.

ALL PAGES

The machine redials the number and resends all pages of the

 

document.

OFF

The machine does not automatically redial the number after a

 

transmission error occurs.

 

 

An asterisk (*) indicates the default setting.

3-24Redialing When the Line Is Busy