System Programming ,

 

 

 

2.If the PC is directly connected to the common equipment, match the data communications parameters of the software program to those now programmed at the telephone system.

-OR-

If remote programming is being employed, the data parameters of the PC must match the modem connected to it. The modem connected.to the common equipment must match the data parameters of it as well.

NOTE: Remember, g-bit data is required for XMODEM protocol. If the common equipment is not now programmed to provide g-bit data, it will have to be re-programmed from station 10 (see page 4-7for details) before data communications can take place. The baud rate to match the modem or the PC should be set at the same time.

Set the data communication parameters as follows:

Press ALT P.

Type 11 the press ENTER. This action selects a baud rate of 9600 baud.

Type 17 then press ENTER. This action selects 8-bit data.

Type 18 the press ENTER. This action selects one stop bit.

Type 24 then press ENTER. This action saves the data parameters.

3.Set the terminal parameters as follows:. Press ALT S.

Type 2 then press ENTER. Type 1 then press ENTER.

Use arrow keys to select VDT-100 or similar emulation then press ENTER.

NOTE: Settino the terminal emulation for a Wvse-50 or VT?00 emulation will provide a whatible set of default values; however, any emulation which provides full duplex operation is satisfactory.

0 Press ESC to finish.

0 Press S then press ENTER. This action saves the terminal parameters.

Press ESC then press ENTER to end the terminal parameter set up.

4. When computer screen displays a prompt for password, type I +# 7 4 6 &then press ENTER. This causes main COS programming menu to be displayed.

5. From main menu, type 1 then press ENTER. This causes system COS programming menu to be displayed.

6.From system menu, make all selections necessary to perform class of service programming then return to the main menu.

7. From the main menu, type 4 then press ENTER. This causes load/save menu to be displayed.

8. From load/save menu, down-load COS data from common equipment to computer or up-load COS data from computer to common equipment,

Down-Load COS Data From Common

Equlpment To Computer

Type 1 then press ENTER.

Press PAGE DOWN.

Type 1 to choose XMODEM protocol.

Type file name for down-loaded COS data to save into.

Press ENTER. The COS data, as programmed in the common equipment, is automatically down-loaded to the computer file.

Up-Load COS Data From Computer To Common Equipment

Type 2 then press ENTER.

Press PAGE UP.

Type 1 to choose XMODEM protocol.

Type file name of saved COS data.

Press ENTER. The COS data, as stored in the computer file, is automatically up-loaded to the common equipment.

9. Repeat step 8 except type 3 to down-load currently stored auto dial and speed dial numbers or type 4 to up-load them.

lO.Retum to main menu and log off.