DigiTech C0408 AtJXILIARY Equipment Interface, Ilon, Flgurs 3-8. Auxiliary Interface Connections

Models: C0408

1 218
Download 218 pages 25.8 Kb
Page 50
Image 50

.ilon

IMI 66-083

AtJXILIARY EQUIPMENT INTERFACE

An industry standard non-electronic telephone device or a data device can be connected on a line ahead of the common equipment. The system can detect an off-hook condition in the connected device and turn on the line sta!us light at the telephones to indicate that the line is busy. Table 3-l(given in Section 1) and Figure 3-8below detail the auxiliary interface connections.

NOTE: When the auxiliary interface feature is being employed, the line to line port reassignment as discussed on pages 3-5 and 4- 19 works as described except in regard to line 2 and line 4. Line 2 can only be reassigned to line port 4 and line 4 can only be reassigned to line port 2

Connection is across tip and ring of lines 2 and 4. The auxiliary interface connections are provided at terminals 1 and 6 of common equipment line jacks 1 and 2.

Flgurs 3-8. Auxiliary Interface Connections

3-16

Page 50
Image 50
DigiTech C0408 system manual AtJXILIARY Equipment Interface, Ilon, Flgurs 3-8. Auxiliary Interface Connections