Connecting to the Storage

Configuring persistent binding using SANsurferCLI

Note: This example uses a v5.x-series driver. The same basic steps would apply for the v3.x-series driver.

QLogic SANsurferCLI is installed in the qliscsi-linux-5.00.4-2-install/directory.

In order to configure persistent binding using the SCLI, use the following command:

qliscsi-linux-5.00.4-2-install/scix

1. In the scix Main Menu, select option 6 for the target menu:

scix Main Menu

main Interactive Menu

-------------------------------------------------------------

Current QLA4010 HBA/Port Information:

HBA Serial Number: FS20403A00911 HBA Port: 0

IP Address:

51.50.51.36

Link: Up

Port Name:

iqn.2000-04.com.qlogic:qla4010.fs20403a00911

Port Alias:

 

 

-------------------------------------------------------------

1.Display General System Information

2.Display Program Version Information

3.List All QLogic iSCSI HBAs detected

4.HBA Options Menu

5.HBA Information

6.Target Menu

7.Diagnostic Menu

8.Display VPD Information

9.Set Working Adapter

10.Exit

enter selection: 6

2. In the scix HBA Target Menu, select option 2 to bind targets and select the desired target ID:

scix HBA Target Menu HBA Target Menu

-------------------------------------------------------------

Current QLA4010 HBA/Port Information:

HBA Serial Number: FS20403A00911 HBA Port: 0

IP Address:

51.50.51.36

Link: Up

Port Name:

iqn.2000-04.com.qlogic:qla4010.fs20403a00911

Port Alias:

-------------------------------------------------------------

1. List Targets

2. Bind Target

138

EMC Host Connectivity with QLogic FC and iSCSI HBAs and FCoE CNAs for the Linux Environment

Page 138
Image 138
EMC P/N 300-002-803 manual Configuring persistent binding using SANsurferCLI, Qliscsi-linux-5.00.4-2-install/scix