Connecting to the Storage

Zoning and connection planning in an iSCSI environment

The user should plan the connectivity of the EMC array to the QLogic iSCSI HBA based on the following considerations:

Be sure to follow the configuration guidelines that EMC outlines. Using improper settings can cause erratic behavior. In particular, note the following:

To achieve load-balancing and multipath failover, storage systems connected to Linux servers should be configured with each QLogic iSCSI HBA port on a different subnet.

A single host cannot mix HBAs and NICs to connect to the same array or different arrays.

A single host cannot attach to a Fibre Array and ISCSI Array at the same time.

Figure xx shows an example of Linux iSCSI with multiple

NICs/HBAs to multiple subnets.

Figure 6 Linux iSCSI with multiple NICs/HBAs to multiple subnets example

Zoning and connection planning in an iSCSI environment

135