Configuring a Boot Device on an EMC Storage Array

Configuring a Symmetrix boot device for iSCSI 3.x

This section describes how to install an EMC-qualified version of Linux onto an EMC Symmetrix storage array connected to an Intel-based x86 and x86_64 class systems and AMD Opteron-based x86_64 class systems.

Preparing the Symmetrix storage array

It is recommended that Volume Logix be enabled on the Symmetrix storage array for LUN masking purposes.

During the installation procedure, only one LUN should be allocated to the host, so that the boot LUN may be identified easily. After the OS installation, additional LUNs may be allocated.

Create a zone that includes the WWPN of the HBA to be used and one iSCSI port. Add the newly-created zone to the zone configuration in the fabric and enable the zone configuration.

Preparing the host

Create a zone that includes the WWPN of the HBA to be used and one iSCSI port. Add the newly-created zone to the zone configuration in the fabric and enable the zone configuration.

The QLogic iSCSI HBA must be the lowest-numbered PCI slot in the server. For example, if there are three adapters in the system in slots 2, 4, and 5, connect the cable to the adapter in slot. Do not connect cables to other adapters until the installation is complete and the host rebooted.

SCSI hard disks are allowed in SAN boot configurations. However, the BIOS for the disk's SCSI adapters must be disabled. Any SCSI disks attached to the host should be disconnected during the operating system installation.

For servers with SCSI CD-ROM drives, ensure that the BIOS is enabled on the SCSI channel that includes the CD-ROM. Disable the BIOS on any other integrated SCSI channels.

For servers with IDE CD-ROM drivers, disable the BIOS on the server's integrated SCSI adapter(s). The SCSI BIOS is not required to boot from the CD-ROM.

168

EMC Host Connectivity with QLogic FC and iSCSI HBAs and FCoE CNAs for the Linux Environment

Page 168
Image 168
EMC P/N 300-002-803 manual Configuring a Symmetrix boot device for iSCSI, Preparing the Symmetrix storage array