Installing and Configuring the BIOS Settings
heading are those that have been tested and determined to be applicable in a Linux environment.
The settings are configurable in NVRAM using the Host Adapter Settings, Advanced Settings, and Extended Firmware Settings menus. To use SANsurfer or the SANsurfer CLI to modify the NVRAM settings, refer to the SANsurfer or SANsurfer CLI documentation from QLogic.
Table 3 |
| QLogic BIOS settings for Fibre Channel HBAs (page 1 of 2) | ||||||
|
|
|
|
|
|
|
| |
|
|
|
| EMC recommended settings |
|
|
| |
|
|
|
|
| ||||
|
| QLogic default | No Multipath functionality | With Multipath functionality | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Host Adapter settings |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Host Adapter BIOS |
| Disabled | • Disabled (No boot from SAN) |
| • Disabled (No boot from SAN) | |||
|
|
|
| • Enabled (Boot from SAN) |
| • Enabled (Boot from SAN) | ||
|
|
|
|
|
|
| ||
Frame Size |
| 2048 | 2048 |
| 2048 |
| ||
|
|
|
|
|
|
| ||
Loop Reset Delay |
| 5 | 5 |
| 5 |
| ||
|
|
|
|
|
| |||
Adapter Hard Loop IP |
| Disabled | Disabled |
| Disabled | |||
|
|
|
|
|
|
| ||
Hard Loop ID |
| 0 | 125 |
| 125 |
| ||
|
|
|
|
| ||||
| Disabled | Disabled | Disabled | |||||
|
|
|
|
|
| |||
Connection Options (topology) |
| 2 | • 1 (FC Fabric environment) |
| • 1 (FC Fabric environment) | |||
|
|
|
| • 0 (FC DAS/Loop environment) |
| • 0 (FC DAS/Loop environment) | ||
|
|
|
|
| ||||
Fibre Channel Tape Support |
| Enabled | Disabled | Disabled | ||||
|
|
|
|
|
|
| ||
Data Rate |
| 2 | 1 |
| 1 |
| ||
|
|
| 2 |
| 2 |
| ||
|
|
| 4 |
| 4 |
| ||
|
|
| 8 |
| 8 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Note: Match port data rate on real |
| Note: Match port data rate on real | ||
|
|
|
| environment. |
| environment. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Advanced Adapter settings |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Execution Throttle |
| 16 | 256 |
| 256 |
| ||
|
|
|
|
|
|
| ||
LUNs per Target |
| 8 | 256 |
| 256 |
| ||
|
|
|
|
|
|
| ||
Enable LIP Reset |
| No |
| No |
| No | ||
|
|
|
|
|
|
|
|
|
40