Special Instructions

CLARiiON CX200 direct-connect dual-host Oracle9i RAC or RHEL

2.1Cluster Manager cluster configurations with QLA234x adapters

For CLARiiON CX200 direct-connect dual-host Oracle9i RAC or RHEL 2.1 Cluster Manager cluster configurations with QLA234x adapters, the default adapter optic jumper position must be changed.

!CAUTION

Modifying the jumper setting without using the recommended firmware and/or drivers may cause a loss of connectivity.

1.Remove the adapter from the server as instructed by the server guide.

2.Locate jumper(s) J3 (QLA2340) or J3 and J4 (QLA2342).

3.Move the jumper(s), onto pins 1–2 (if not already there).

To return the jumper(s) to the default factory position, move the jumper(s) back to pins 2–3.

212

EMC Host Connectivity with QLogic FC and iSCSI HBAs and FCoE CNAs for the Linux Environment

Page 212
Image 212
EMC P/N 300-002-803 manual Special Instructions