EMC Host Connectivity with QLogic FC and iSCSI HBAs and FCoE CNAs for the Linux Environment
Special Instructions
CLARiiON CX200 direct-connect dual-host Oracle9i RAC or RHEL
2.1 Cluster Manager cluster configurations with QLA234x
adapters
For CLARiiON CX200 direct-connect dual-host Oracle9i RAC or
RHEL 2.1 Cluster Manager cluster configurations with QLA234x
adapters, the default adapter optic jumper position must be changed.
CAUTION
!
Modifying the jumper setting without using the recommended
firmware and/or drivers may cause a loss of connectivity.
1. Remove the adapter from the server as instructed by the server
guide.
2. Locate jumper(s) J3 (QLA2340) or J3 and J4 (QLA2342).
3. Move the jumper(s), onto pins 1–2 (if not already there).
To return the jumper(s) to the default factory position, move the
jumper(s) back to pins 2–3.