Table
Sensor or switch | Sensor | Replacement part | Description | Testing of sensor | |
name | number | number |
| test name |
|
|
|
|
|
|
|
Paper feeder Tray 4 | PS451 | Photointerrupter | P Tray 4 paper | Remove the Tray 4 | |
cassette media- |
|
|
| sensor | cassette, and then |
presence sensor1 |
|
|
|
| push the sensor |
|
|
|
|
| lever. |
|
|
|
|
|
|
Paper feeder Tray 4 | PS461 | Photointerrupter | Q Tray 3 detect | Remove the Tray 4 | |
cassette presence |
|
|
| sensor | cassette, and then |
sensor1 |
|
|
|
| reinstall it. |
1Tray 3 and Tray 4 use PS451 and PS461 sensors.
Access the MANUAL SENSOR TEST or the MANUAL SENSOR TEST 2 in the DIAGNOSTICS menu.
1.Press the Menu button .
2.Press the down arrow button or the up arrow
button to navigate to the DIAGNOSTICS menu, and then press the OK button.
3.Press the down arrow button or the up arrow
button to navigate to the MANUAL SENSOR TEST or MANUAL SENSOR TEST 2 menu, and then press the OK button.
4.Press the down arrow button or the up arrow
button to highlight a test, and then press the OK button to select the test.
5.To exit the diagnostic test, press the stop button , and then select EXIT DIAGNOSTICS.
NOTE: Menus are not available during a test. During a test, the OK button functions like the stop button
.
ENWW | Tools for troubleshooting 139 |