Removal and replacement strategy
General cautions during removal and replacement
This chapter describes the removal and replacement of
Replacing FRUs is generally the reverse of removal. Occasionally, notes and tips are included to provide directions for difficult or critical replacement procedures.
HP does not support repairing individual subassemblies or troubleshooting to the component level.
WARNING! Turn the product off, wait 5 seconds, and then remove the power cord before attempting to service the product. If this warning is not followed, severe injury can result, in addition to damage to the product. The power must be on for certain functional checks during troubleshooting. However, disconnect the power supply during parts removal.
Never operate or service the product with the protective cover removed from the laser/scanner assembly. The reflected beam, although invisible, can damage your eyes.
The
CAUTION: Do not bend or fold the flat flexible cables (FFCs) during removal or installation. Also, do not straighten prefolds in the FFCs. You must fully seat all FFCs in their connectors. Failure to fully seat an FFC into a connector can cause a short circuit in a PCA.
Incorrectly routed or loose wire harnesses can interfere with other internal components and can become damaged or broken. Frayed or pinched harness wires can be difficult to find. When replacing wire harnesses, always use the provided wire loops, lance points, or
NOTE: To install a
Note the length, diameter, color, type, and location of each screw. Be sure to return each screw to its original location during reassembly.
TIP: For clarity, some photos in this chapter might show components removed that would not be removed to service the product. If necessary, remove the components listed at the beginning of a procedure before proceeding to service the product.
Electrostatic discharge
CAUTION: |
| Some parts are sensitive to electrostatic discharge (ESD). Look for the ESD reminder |
|
|
|
when removing product parts. Always perform service work at an
Protect the
Required tools
●#2 Phillips 152 mm (6 in) screwdriver with magnetic tip
●#2 Phillips 76 mm (3 in) screwdriver with magnetic tip
●Small flat blade screwdriver
46 Chapter 2 Removal and replacement | ENWW |