4.Press the down arrow button or the up arrow button to select a component to test.

Table 3-6Components test

Component test

Item

Control-panel display

Description

 

 

message

 

 

 

 

 

Main motor test

M8001

DRUM MOTOR

Activates the main motor for 10 seconds.

 

 

 

 

Scanner motor test

Not

LASER SCANNER MOTOR

Activates the laser/scanner motor for 10

 

applicabl

 

seconds.

 

e

 

 

 

 

 

 

Fuser motor test

M8002

FUSER MOTOR

Activates the fuser motor for 10 seconds.

 

 

 

 

Clutch drive test

CL1

INT FEED ROLLER CLUTCH

Activates the main motor to activate the

 

 

 

paper feeder pickup clutch for 10 seconds.

 

 

 

 

Ttay 1 (multipurpose tray)

SL1

MP TRAY SOLENOID DRIVE

Activates the Tray 1 pickup solenoid for 10

pickup solenoid test

 

 

seconds.

 

 

 

 

Tray 2 pickup solenoid test

SL2

TRAY 2 PICKUP SOLENOID

Activates the Tray 3 cassette pickup

 

 

 

solenoid for 10 seconds.

 

 

 

 

Tray 3 pickup solenoid test

SL31

TRAY 3 PICKUP SOLENOID

Activates the Tray 4 cassette pickup

 

 

 

solenoid for 10 seconds.

 

 

 

 

Tray 4 pickup solenoid test

SL31

TRAY 4 PICKUP SOLENOID

Activates the Tray 2 cassette pickup

 

 

 

solenoid for 10 seconds.

1 Tray 3 and Tray 4 both use a SL3.

5.Press the OK button to start the test.

ENWW