Component tests
Half self-test
Perform a half
NOTE: It might be easier to perform the print/stop test to stop the product during the printing process. See Print/stop test on page 157.
1.Print a configuration page from the control panel.
2.Open the cartridge door after the paper advances
3.Remove the print cartridge.
4.Open the print cartridge drum shield to view the drum surface.
If a dark and distinct toner image is present on the drum surface, assume that the cleaning, conditioning, writing, and developing functions of the electrophotographic process are functioning correctly. Troubleshoot the failure as a transfer or fusing problem. If no image is present on the drum, perform the drum rotation test check. See Drum rotation test check on page 158.
Drum rotation test check
NOTE: This test is especially important if refilled print cartridges are in use.
The photosensitive drum, which is located in the print cartridge, must rotate in order for the print process to work. The photosensitive drum receives its drive from the main gear assembly. Use this procedure to determine whether the drum is rotating.
1.Open the cartridge door.
2.Remove the print cartridge.
3.Mark the cartridge drive gear with a
4.Install the print cartridge, and then close the cartridge door. The
5.Open the product and inspect the mark on the cartridge drive gear.
Verify that the mark moved. If there was no movement, inspect the main gear assembly to make sure that it connects with the
Diagnostics menu components test
Use this diagnostic test to isolate and test individual product components.
1.Press the Menu button .
2.Press the down arrow button or the up arrow
button to navigate to the DIAGNOSTICS menu, and then press the OK button.
3.Press the down arrow button or the up arrow
button to navigate to the COMPONENT TEST sub menu, and then press the OK button.
158 Chapter 3 Solve problems | ENWW |