The
●Fuser heater (H1); heats the fusing film
●Thermistor (TH1 and TH2); detects the fuser temperature (contact type)
◦Main thermistor (TH1); controls the temperature in the fuser (contact type)
◦Sub thermistor (TH2); detects a
●Thermoswitch (TP1); prevents abnormal temperature rise in the fuser (contact type)
Figure
H1 | Fuser film |
|
TP1
TH1
Pressure roller
TH2
FUSER TEMPERATURE signal
FUSER HEATER CONTROL signal
| Fuser heater control |
| Fuser heater safety |
DC controller | circuit |
| circuit |
|
|
|
|
Fuser control circuit
Engine controller unit
16 Chapter 1 Theory of operation | ENWW |