8: Device Ports
SLBâ„¢ Branch Office Manager User Guide 103

PC Card Logging

PC Card Logging Select to enable PC Card logging. A PC Card Compact
Flash must be loaded into one of the PC Card slots on the
front of the SLB branch office manager and properly
mounted ((see PC Card Logging on page 99). Disabled by
default.
Log To If port logging is to a PC Card, select the slot (Upper or
Lower) in which the PC Card has been inserted. Upper is
the default.
Max Number of
Files The maximum number of files to create to contain log data
to the port. These files keep a history of the data received
from the port. Once this limit is exceeded, the oldest file is
overwritten. The default is 10.
Max Size of Files The maximum allowable file size in bytes. The default is
2048 bytes. Once the maximum size of a file is reached,
the SLB device begins generating a new file. The default is
2048 bytes.

Syslog Logging

Syslog Logging Select to enable system logging.
Note: The logging level for the device ports log must be
set to Info to view Syslog entries for Device Port logging on
the Services page.
Note: To apply the settings to additional device ports, in the Apply settings to Device
Ports field, enter the additional ports, (e.g., 1-3, 5, 6)
3. To apply settings to other device ports in addition to the currently selecte d port,
select the Apply settings to Device Ports and enter port numbers separated b y
commas. Indicate a range of port numbers with a hyphen (e.g., 2, 5, 7-10), an d
separate ranges with commas.
4. To save, click the Apply button.
Logging Commands
The following CLI commands correspond to the web page entries describ ed above.
To configure logging settings for one or more device ports:
Example: set deviceport port 2-5,6,12,15-16 baud 2400 locallogging
enable
Note: Local logging must be enabled for a device port for the locallog commands to be
executed. To use the set locallog clear command, the user must have permission to clear
port buffers (see 11: User Authentication).
set deviceport port <Device Port List or Name> <one or more
deviceport parameters>
Parameters:
emaildelay <Email Delay>
emaillogging <disable|bytecnt|charstr>