2: Overview

The SLB device also provides features such as convenient text menu systems, break- safe operation, port buffering (logging), remote authentication, and Secure Shell (SSH) access. Dial-up modem support ensures access when the network is not available.

Models

Two SLB models have the following hardware components:

Two Models: The SLB branch office manager is available in a 100-120 VAC output model (SLB088411-01) with NEMA 5-15R type outlets and a 208-240 VAC output model (SLB088412-01) with IEC60320/C13 type outlets.

Power Outlets: Each model has four outlets that allow power management and control (on/off/reboot) of the attached equipment using a simple web or command line interface.

Serial Device Ports: Eight serial RS-232C (EIA-232) device ports are for remote console management of the attached equipment. These match the RJ45 pin-outs of the console ports of many popular devices found in a network environment, and where different can be converted using Lantronix adapters. See D: Adapters and Pinouts for more information on serial adapters and pin-outs.

Unmanaged Ethernet Switch: A built-in 8-port unmanaged Ethernet switch provides convenience and helps further reduce required rack space.

Ports and Modem Slots: The SLB branch office manager has two 10/100 Ethernet ports (referred to in this User Guide as Eth1 and Eth2) and a front panel serial console port (RJ45). The SLB device has two 32-bit CardBus (PC card) slots to support storage cards or a PC Card modem for dial-in access. The list of supported cards is available on the Lantronix website.

 

Table 2-1. SLB Models

 

 

 

Part Number

 

Model and Description

SLB088411-01

 

SLB branch office manager, 8 device ports, 8 Ethernet switch

 

 

ports, 4 power outlets (100-120 VAC, NEMA 5-15R type), 1 AC

 

 

power supply

 

 

 

SLB088412-01

 

SLB branch office manager, 8 device ports, 8 Ethernet switch

 

 

ports, 4 power outlets (208-240 VAC, IEC60320/C13 type), 1

 

 

AC power supply

 

 

 