Lantronix 900-510 manual To monitor a device port

Models: 900-510

1 280
Download 280 pages 10.49 Kb
Page 132
Image 132

10: Connections

To monitor a device port:

connect listen deviceport <Device Port # or Name>

To connect a device port to another device port or an outbound network connection (data flows in both directions):

connect bidirection <Port # or Name> <endpoint>

Endpoint is one of:

charcount <# of Chars> charseq <Char Sequence> charxfer <toendpointfromendpoint> deviceport <Device Port # or Name> date <MMDDYYhhmm[ss]>

exclusive <enabledisable>

ssh <IP Address or Name> [port <TCP Port] [<SSH flags>]

where <SSH flags> is one or more of: user <Login Name>

version <12>

command <Command to Execute> tcp <IP Address> [port <TCP Port>]

telnet <IP Address or Name> [port <TCP Port>]

trigger <nowdatetimechars>

udp <IP Address> [port <UDP Port>]

Note: If the trigger is datetime (establish connection at a specified date/time), enter the date parameter. If the trigger is chars (establish connection on receipt of a specified number or characters or a character sequence), enter the charxfer parameter and either the charcount or the charseq parameter.

To connect a device port to another device port or an outbound network connection (data flows in one direction):

connect unidirection <Device Port # or Name> dataflow <toendpointfromendpoint> <endpoint>

Endpoint is one of:

charcount <# of Chars> charseq <Char Sequence> datetime <MMDDYYhhmm[ss]> deviceport <Port # or Name> exclusive <enabledisable>

SLB™ Branch Office Manager User Guide

132

Page 132
Image 132
Lantronix 900-510 manual To monitor a device port