Lucent Technologies MDW 9031DCP manual Single Carrier Installation Self-Test, Control

Models: MDW 9031 MDW 9031DCP

1 161
Download 161 pages 39.52 Kb
Page 48
Image 48

2 Installing the MDW 9031/9031DCP Pocket Phone

Installing a Single Carrier

 

 

 

 

Single Carrier Installation Self-Test

To perform a single carrier self-test:

1A single carrier must always function as a control carrier. Wait a few seconds, then check the LED(s) on the right side of the carrier:

~Model 117A4:

Compare the OUT OF SYNC and CONTROL/EXPANSION LEDs against the top three lines on the “SYNC and CONTROL/EXP LED Codes” label.

~Model 117A3:

The 117A3 has no CONTROL/EXPANSION LED. The OUT OF SYNC LED should not be lit.

2If the OUT OF SYNC LED is lit, power down, wait at least 15 seconds, and then repower the carrier. If the LED is still lit, follow the suggestions in the “Installation Problems” section of Chapter 5, “Troubleshooting.” If the LED is still lit, call Customer Support as described in the Copyright and Legal Notices at the beginning of this book.

 

 

YNC

 

OF

S

 

OUT

 

 

CONTROL/

4

EXPANSION

 

40 Issue 3 October 1999

MDW 9031/9031DCP Wireless Pocket Phone Installation and Use 503-801-166

Page 48
Image 48
Lucent Technologies MDW 9031DCP manual Single Carrier Installation Self-Test, Control