Procedures |
| Troubleshooting 5 |
|
|
|
Voice Quality Problems
Symptom | Possible Causes | Possible Solutions | |
|
|
| |
Handset voice quality | A competing radio device (for | Place the handset in Wireless Test | |
and range are not as | example, a wireless | Mode as described in Chapter 3. If | |
good as they were | has been installed in the area. Both | the signal strength and voice quality | |
before. | products are competing for the same | readings are low, look for a newly | |
| air space and will conflict when both | installed radio device nearby. | |
| are being used. | Remove it or move your handset’s | |
|
| matching radio module at least 6 | |
|
| feet (1.8 m) away from the potential | |
|
| interference. | |
| Carrier(s) are out of synchronization | For a | |
| (the OUT OF SYNC LED is lit). | 1 | Power down. |
|
| ||
|
| 2 | Wait 15 seconds, then repower |
|
|
| the carrier. |
|
| For a | |
|
| 1 Verify that all expansion cables | |
|
|
| are fully inserted in the correct |
|
|
| IN and OUT jacks. |
|
| 2 | Check CONTROL/ |
|
|
| EXPANSION LEDs for correct |
|
|
| color. (See “Understanding |
|
|
| Your Model 117A4 Carrier” in |
|
|
| Chapter 2.) |
|
| 3 Ensure that each carrier has at | |
|
|
| least one radio module |
|
|
| installed. |
|
|
| If the control carrier is a Model |
|
|
| 117A3, ensure that there is a |
|
|
| radio module in Slot 6. |
|
| 4 Power down all carriers, wait | |
|
|
| 15 seconds, repower the control |
|
|
| carrier, then repower the |
|
|
| expansion carriers in order, |
|
|
| from left to right. |
| Antenna of the radio module is too | Reinstall the radio module or | |
| close to the ceiling. | carrier(s) so that the top of the radio | |
|
| module antenna is 6 to 12 inches | |
|
| (15.2 to 30.5 cm) from the ceiling. | |
|
|
|
|
MDW 9031/9031DCP Wireless Pocket Phone Installation and Use | Issue 3 October 1999 111 |