CHAPTER 6 USB CONTROLLER
Preliminary User’s Manual S15543EJ1V0UM 315
Bits Field R/W Default Description
8 EP1FU RC 0 EP1 FIFO Error:
Bit that indicates that an underrun has occurred for the FIFO of EndPoint1
(Isochronous IN). When the FIFO empties while EndPoint1 is performing a
transaction, this bit is set to a ‘1’.
This bit is reset to a ‘0’ when the VR4120A reads this register.
7 EP6RF RC 0 EP6 Rx Finished:
Bit that indicates that EndPoint6 (Interrupt OUT) has completed the receiving
of a data segment and issued the Rx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.
6 EP5TF RC 0 EP5 Tx Finished:
Bit that indicates that EndPoint5 (Interrupt IN) has completed the transmitting
of a data segment and issued the Tx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.
5 EP4RF RC 0 EP4 Rx Finished:
Bit that indicates that EndPoint4 (Bulk OUT) has completed the receiving of a
data segment and issued the Rx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.
4 EP3TF RC 0 EP3 Tx Finished:
Bit that indicates that EndPoint3 (Bulk IN) has completed the transmitting of a
data segment and issued the Tx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.
3 EP2RF RC 0 EP2 Rx Finished:
Bit that indicates that EndPoint2 (Isochronous OUT) has completed the
receiving of a data segment and issued the Rx Indication.
The timing when this bit will be set varies with Rx Mode.
This bit is reset to a ‘0’ when the VR4120A reads this register.
2 EP1TF RC 0 EP1 Tx Finished:
Bit that indicates that EndPoint1 (Isochronous IN) has completed the
transmitting of a data segment and issued the Tx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.
1 EP0RF RC 0 EP0 Rx Finished:
Bit that indicates that EndPoint0 (Control) has completed the receiving of a
data segment and issued the Rx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.
0 EP0TF RC 0 EP0 Tx Finished:
Bit that indicates that EndPoint0 (Control) has completed the transmitting of a
data segment and issued the Tx Indication.
This bit is reset to a ‘0’ when the VR4120A reads this register.