3 Tests and Diagnostics | 3.4 Setting of the hardware configuration |
Setting of the HWSC
Setting of the UUID
Display of the DMI information (including UUID)
Setting of DVD region code (Yes/No)
After completion of the above settings, H/W configuration & DMI information are appeared in order. Check the contents and press Enter.
Subtest 02 | Region write |
|
|
| This subtest executes the setting of the region code for DVD drive based on | ||
| the destination of the machine. |
| |
| When the region code is already written, test ends without setting. | ||
| The following message appears in the display after setting the region code. | ||
| Press any key to return to the H/W initial information setting tool menu. | ||
| *********************************** | ||
| ******* | It completed | ******* |
| *********************************** | ||
| * |
| * |
| Press any key to continue... | ||
Subtest 03 | DMI information save |
|
|
NOTE: Before replacing the system board, be sure to execute this subtest and save the DMI information to the floppy disk.
This is one of tools to copy the DMI information to a new PCB after replacing.
This subtest saves all the DMI data in a floppy disk.
Subtest 04 DMI information recovery
NOTE: 1. After replacing the system board, be sure to execute this subtest and copy the DMI information to a new system board.
2.Since the data of UUID is updated every time when this subtest, DMI information recovery, is done, the saved UUID data is not written
This is one of tools to copy the DMI information to a new PCB after replacing.
This subtest writes all the DMI data in the floppy disk into the new PCB.
QOSMIO G20 Maintenance Manual | [CONFIDENTIAL] |