J.3Operation of Independent utility

Appendix J Maintenance of TOSHIBA RAID

3.When [Rebuild Range] menu is displayed, the range to be rebuilt is designated. When [Effective] is selected, rebuild limit becomes valid and it rebuilds up to the rebuild limit. When [Whole] is selected, it rebuilds maximum capacity of array. The [Rebuild Range] menu is not displayed when the rebuild limit is not set or the rebuild limit is the same as the maximum capacity of array. Normally designation of [Effective] is adequate.

4.Put the cursor on “OK” in [Confirmation] and press [Enter] key. The rebuild starts.

CAUTION: When the rebuild starts, the data of drive rebuilt is lost.

5.During rebuilding, [Status] of [Physical Drive] becomes “Rebuilding” and the progress rate, expected remaining time and the number of errors are displayed. During rebuilding, the [Rebuilding] dialog to select [Suspend] or [Abort] is displayed. It may take time depending on the drive capacity.

6.To suspend the rebuilding, put the cursor on [Suspend] (when aborting, on the [Abort]) and press [Enter] key. When [Confirmation] is displayed, put the cursor on [OK] and press [Enter] key. During being suspended, [Suspend] is displayed in [Progress] of [Physical Drive].

7.When “Rebuild Limit” is set and [Rebuild Range] is set to [Whole], only [Finish] is can be selected after exceeding the Rebuild Limit. When [Finish] is selected and “OK” is selected in [Confirmation], the rebuilding is completed at the time. When OS is booted after exceeding the Rebuild Limit, the rebuild is completed.

J-16

[CONFIDENTIAL]

QOSMIO G20 Maintenance Manual (960-511)

Page 432
Image 432
Toshiba QOSMIO G20 manual Confidential