J.3Operation of Independent utility

Appendix J Maintenance of TOSHIBA RAID

(2) Display of Logical/Physical Drive

Logical Drive

The status of RAID array is displayed in Logical Drive by array. The displayed items are follows.

 

Table J-2 Displayed item in Logical Drive

 

 

 

 

 

Explanation

 

 

 

Status

 

Displays the status of array. The contents are follows.

(Status of array)

 

-OPTIMALThe array works normally.

 

 

-DEGRADEThe array is degraded.

 

 

-CRITICALThe array is failed. It can not be used.

 

 

 

RAID Level

 

Displays the RAID level.

 

 

 

# of Drive

 

Displays the number of physical drives incorporated in the array.

 

 

 

RAID ID

 

Displays peculiar ID by array.

 

 

 

Capacity

 

Displays the capacity of array.

 

 

 

Stripe Size

 

Item that is not set item.

 

 

 

Write Cache

 

Displays the setting of drive write cache. “Enable” or “Disable” is

 

 

displayed. The default is “Enable”. This option is displayed in RAID-1

 

 

(Mirroring).

 

 

 

Degrade Bootup

 

Displays if boot OS or not when the array is degraded. “Yes” (Boot up)

 

 

or “No” (Not boot up) is displayed. The default is “Yes”. This option is

 

 

displayed in RAID-1 (Mirroring).

 

 

 

MBR Protection

 

Displays the setting of protection function of MBR (Master Boot

 

 

Record). “Enable” (Protect) or “Disable” (Not protect) can be selected.

 

 

The default is “Disable”.

 

 

When OS is installed by SetupInstructor, it is set automatically to

 

 

“Enable”. When OS is installed manually, it is set to “Enable”. If

 

 

necessary, change the setting.

S.M.A.R.T.

 

Displays the setting of failure prediction function of drive. “Enable” or

 

 

“Disable” is displayed. The default is “Enable”.

 

 

 

Last MC

 

Displays the date when checking of media or rebuilding of array

 

 

executed last. It displays “00/00/00” right after making new array or

 

 

when the rebuild limit is changed.

J-10