4.30 Touch sensor board

4 Replacement Procedures

4.30Touch sensor board

Removing the touch sensor board

The following describes the procedure for removing touch sensor (See Figure 4-43).

1.Disconnect the touch sensor flat cable from the connector on the touch sensor board.

2.Peeling off the insulator, remove the following screws securing the touch sensor plate and remove the touch sensor plate.

‰ M2.5x4.0B FLAT BIND screw

x9

3. Pull up and remove the touch sensor board from the cover assembly.

CAUTION: The removed touch sensor board is not reusable. Therefore when installing the touch sensor board, it must be a new one.

M2.5x4.0B FLAT BIND

Touch sensor flat cable

M2.5x4.0B FLAT BIND

Touch sensor plate

Touch sensor board

Insulator

Figure 4-43 Removing the touch sensor board

4-68

[CONFIDENTIAL]

QOSMIO G20 Maintenance Manual (960-511)

Page 310
Image 310
Toshiba QOSMIO G20 manual Touch sensor board Replacement Procedures, Removing the touch sensor board