Appendix J Maintenance of TOSHIBA RAID

J.3Operation of Independent utility

 

[View Drive Log] menu is as follows

 

 

 

 

Table J-10 Content of View Drive Log menu

 

 

 

 

 

 

Option

 

Explanation

 

 

 

 

 

 

Change Port

Changes the display of the own log and redundant log. At the

 

 

 

beginning, the Port-0’s own log and the redundant log are displayed.

 

 

Go to Event

When this option selected, it moves to the log with designated

 

 

 

number.

 

 

 

 

 

 

 

The key function in [View Drive Log] key is as follows.

 

Table J-11 Function of key in View Drive Log

 

 

 

Key

 

Function

 

 

 

[PageUp]

 

Scrolls upward step one by one.

 

 

 

[PageDown]

 

Scrolls downward step one by one.

 

 

 

[Home]

 

Jumps to the oldest log in the latest 7,168 logs.

 

 

 

[End]

 

Jumps to the latest log.

 

 

 

[Ctrl][Home]

 

Jumps to the oldest log that is older than 7,168 logs and the

 

 

identification ID is recorded.

[Tab]

 

Switches [OWN] window and [REDUNDANT] window.

 

 

 

Force OFFLINE

Selecting this option in [Physical Drive] menu of Setup Utility can set the physical drive to offline by force. Follow the procedure below.

1.Select [Physical Drive] in [Main Menu].

2.Select [Force OFFLINE] in [Physical Drive].

3.Select the drive that you want to set it to offline with [Space] key in [Physical Drive] and press [Enter] key.

4.Selecting “OK” in [Confirmation] stores the setting.

Scan

When [Scan] in [Physical Drive] menu is selected, it scans physical drive. This is used to recognize the drive after replacing failed drive.

QOSMIO G20 Maintenance Manual (960-511)

[CONFIDENTIAL]

J-27

Page 443
Image 443
Toshiba QOSMIO G20 Table J-10 Content of View Drive Log menu, Table J-11 Function of key in View Drive Log, Force Offline