2 Troubleshooting Procedures

2.4 System Board Troubleshooting

Table 2-4 Debug port (Boot mode) error status (3/8)

D port status

Inspection items

Details

 

 

 

F101h

Checking DRAM type and size

When unsupported memory connected, beeps

 

and halts.

 

(at cold boot)

 

(When DRAM size = o, it halts.)

 

 

 

 

 

 

Testing the stack area of SM-

(When it can not be used, halts.)

 

RAM

 

 

 

 

 

F102h

Configuring cache memory

 

 

 

 

 

Permission of L1/L2 cache

 

 

memory

 

 

Checking the access of a

(When error detected, it halts.)

 

CMOS (Only in Cold Boot)

 

 

 

 

 

 

Examining the battery level of

 

 

CMOS

 

 

 

 

 

Checksum check of CMOS

 

 

 

 

 

Initializing data in CMOS (1)

 

 

 

 

 

Setting up IRT status

(Setting of boot status and IRT busy flag, The

 

rest bit is 0)

 

 

 

Storing the size of DRAM

 

 

 

 

F103h

Branch of resuming

When a CMOS error is detected, no resume

 

(only in Cold Boot)

occurs.

 

 

 

 

 

If “resume status code” is not set, no resume

 

 

occurs.

 

 

Resume error check

 

 

S3 recovery error (ICH)

 

 

Resume error F17AH

 

 

SM-RAM checksum check

 

 

Resume error F173H

 

 

Memory configuration change check

 

 

Resume error F173H

 

 

Checksum check of system BIOS RAM area

 

 

Resume error F179H

 

 

Checksum check of expansion memory

 

 

Resume error F176H

 

 

Checksum check of PnP RAM

 

 

Resume error F177H

 

 

To resume process (RESUME_MAIN)

 

 

 

 

Resume error process

Returns the CPU clock to “Low”

 

 

 

 

 

Prohibition of all SMI

 

 

 

 

 

Clears resume status

 

 

 

 

 

Return to ROM

 

 

 

QOSMIO G20 Maintenance Manual (960-511)

[CONFIDENTIAL]

2-23